✨ Welcome to the new Discount Equipment site — same 36-year team, freshly redesigned.
36 Years of Industry Leadership · Trusted by Contractors Across America · U.S. Freight & Exporter-Friendly
MultiQuip

Multiquip QP4TK Trash Pump, 4" Suction/Discharge, 475 GPM, 85 ft. MAX Head; 9.5 HP, Kubota OC95-E4 Diesel Engine

Part number
QP4TK
Model
QP4TK
Year
2/1/2026
Condition
New
$6201.36List $7776.00Save $1574.64

MultiQuip orders have a $50.00 minimum (Multiquip family)

Genuine OEMShips nationwideFree shippingExpert support
Multiquip QP4TKTrash Pump, 4" Suction/Discharge, 475 GPM, 9.5 HP Kubota OC95-E4 Diesel Engine Powerful, dependable 4" industrial centrifugal trash pump that is the professional’s choice for the toughest dewatering applications. The signature Multiquip aluminum pump-end casings and high quality internal components provide the fastest priming times and trusted operational life. The pump is powered by an electric start, KUBOTA OC95-E4 diesel engine that provides EPA/CARB compliance design. This pump is the ideal choice for dewatering operations such as: excavations, flood waters, sewage by-pass, water transfer, and barge cleaning. * Not designed to pump salt water and selected chemicals. Feature Die-cast aluminum casings to promote fast priming times. Rugged, EPA/CARB Certified 9.5HP KUBOTA diesel engine. Electric start for operating convenience. Engineered for 475 GPM flow rate. Maximum Head - 85'. Pumps water with solid content as large as 2" in diameter. Dual 4" discharge ports for operational and application flexibility. Silicon/carbon mechanical seal for durability. Large clean-out chamber design for efficient. Tubular Steel frame for transportation and pump protection. #45 Ductile iron impeller and volute for abrasion resistance/long life. Shock mounted pump design to minimize operating harmonics. Optional UWK4 Wheel Kit available
Multiquip QP4TKTrash Pump, 4" Suction/Discharge, 475 GPM, 9.5 HP Kubota OC95-E4 Diesel Engine • Die-cast aluminum casings to promote fast priming times. • Rugged, EPA/CARB Certified 9.5HP KUBOTA diesel engine. • Electric start for operating convenience. • Engineered for 475 GPM flow rate. • Maximum Head - 85'. • Pumps water with solid content as large as 2" in diameter. • Dual 4" discharge ports for operational and application flexibility. • Silicon/carbon mechanical seal for durability. • Large clean-out chamber design for efficient. • Tubular Steel frame for transportation and pump protection. • #45 Ductile iron impeller and volute for abrasion resistance/long life. • Shock mounted pump design to minimize operating harmonics. • Optional UWK4 Wheel Kit available
Multiquip QP4TK Trash Pump Multiquip QP4TZ Specifications Unit Specifications Suction x Discharge (mm) 4 x 4 (100 x 100) Maximum Water Capacity (L) 475 gpm (2000 L/min) Maximum Lift (m) 25 ft (7.6) Maximum Head (m) 85 ft. (26) Maximum Pressure (kPA) 37.7 psi (253) Maximum Solids (mm) 2 " (51) Optional Wheel Kit UWK Dimensions & Weights Overall Length (mm) 30.5 in. (775) Overall Width (mm) 24.5 in. (6922) Overall Height (mm) 28.5 in. (724) Operating Weight (kg) 286 lbs (130)
Multiquip QP4TK Trash Pump GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the influence of drugs or alcohol. NOTICE This equipment should only be operated by trained and qualified personnel 18 years of age and older. Whenever necessary, replace nameplate, operation and safety decals when they become difficult read. Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties. „ NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result. ALWAYS know the location of the nearest fire extinguisher. ALWAYS know the location of the nearest first aid kit. ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency. PUMP SAFETY DANGER NEVER pump volatile, explosive, flammable or low flash point fluids. These fluids could ignite or explode. The engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. The engine of this equipment requires an adequate free flow of cooling air. NEVER operate this equipment in any enclosed or narrow area where free flow of the air is restricted. If the air flow is restricted it will cause injury to people and property and serious damage to the equipment or engine. NEVER operate the equipment in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death. WARNING NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance. NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug. The possibility exists of scalding, resulting in severe bodily harm. NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties. CAUTION NEVER lubricate components or attempt service on a running machine. NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat. NOTICE ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump and mechanical seal. In winter drain water from pump housing to prevent freezing. „NEVER start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it. Before starting the pump, check that the clean-out cover is securely fastened. ALWAYS keep the machine in proper running condition. ALWAYS ensure pump is on level ground before use. Fix damage to machine and replace any broken parts immediately. ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel. ENGINE SAFETY WARNING NEVER operate the engine with heat shields or guards removed. DO NOT remove the engine oil drain plug while the engine is hot. Hot oil will gush out of the oil tank and severely scald any persons in the general area of the pump. CAUTION NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing equipment. NOTICE NEVER run engine without an air filter or with a dirty air filter. Severe engine damage may occur. Service air filter frequently to prevent engine malfunction. NEVER tamper with the factory settings of the engine or engine governor. Damage to the engine or equipment can result if operating in speed ranges above the maximum allowable. FUEL SAFETY DANGER DO NOT add fuel to equipment if it is placed inside truck bed with plastic liner. Possibility exists of explosion or fire due to static electricity. DO NOT start the engine near spilled fuel or combustible fluids. Fuel is extremely flammable and its vapors can cause an explosion if ignited. ALWAYS refuel in a well-ventilated area, away from sparks and open flames. ALWAYS use extreme caution when working with flammable liquids. DO NOT fill the fuel tank while the engine is running or hot. DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in appropriate containers, in well-ventilated areas and away from sparks and flames. NEVER use fuel as a cleaning agent. DO NOT smoke around or near the equipment. Fire or explosion could result from fuel vapors or if fuel is spilled on a hot engine. BATTERY SAFETY (ELECTRIC START ONLY) DANGER DO NOT drop the battery. There is a possibility that the battery will explode. DO NOT expose the battery to open flames, sparks, cigarettes, etc. The battery contains combustible gases and liquids. If these gases and liquids come into contact with a flame or spark, an explosion could occur. WARNING ALWAYS wear safety glasses when handling the battery to avoid eye irritation. The battery contains acids that can cause injury to the eyes and skin. Use well-insulated gloves when picking up the battery. ALWAYS keep the battery charged. If the battery is not charged, combustible gas will build up. DO NOT charge battery if frozen. Battery can explode. When frozen, warm the battery to at least 61°F (16°C). ALWAYS recharge the battery in a well-ventilated environment to avoid the risk of a dangerous concentration of combustible gases. If the battery liquid (dilute sulfuric acid) comes into contact with clothing or skin, rinse skin or clothing immediately with plenty of water. If the battery liquid (dilute sulfuric acid) comes into contact with eyes, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention. CAUTION ALWAYS disconnect the NEGATIVE battery terminal before performing service on the equipment. ALWAYS keep battery cables in good working condition. Repair or replace all worn cables. TRANSPORTING SAFETY CAUTION NEVER allow any person or animal to stand underneath the equipment while lifting. NOTICE Before lifting, make sure that the equipment parts (hook and vibration insulator) are not damaged and screws are not loose or missing. Always make sure crane or lifting device has been properly secured to the lifting bail (hook) of the equipment. ALWAYS shutdown engine before transporting. NEVER lift the equipment while the engine is running. Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling. Use adequate lifting cable (wire or rope) of sufficient strength. Use one point suspension hook and lift straight upwards. DO NOT lift machine to unnecessary heights. ALWAYS tie down equipment during transport by securing the equipment with rope. NOTICE Decommissioning is a controlled process used to safely retire a piece of equipment that is no longer serviceable. If the equipment poses an unacceptable and unrepairable safety risk due to wear or damage or is no longer cost effective to maintain (beyond life-cycle reliability) and is to be decommissioned (demolition and dismantlement),be sure to follow rules below. DO NOT pour waste or oil directly onto the ground, down a drain or into any water source. Contact your country's Department of Public Works or recycling agency in your area and arrange for proper disposal of any electrical components, waste or oil associated with this equipment. When the life cycle of this equipment is over, remove battery and bring to appropriate facility for lead reclamation. Use safety precautions when handling batteries that contain sulfuric acid. „When the life cycle of this equipment is over, it is recommended that the trowel frame and all other metal parts be sent to a recycling center. Metal recycling involves the collection of metal from discarded products and its transformation into raw materials to use in manufacturing a new product. Recyclers and manufacturers alike promote the process of recycling metal. Using a metal recycling center promotes energy cost savings EMISSIONS INFORMATION NOTICE The diesel engine used in this equipment has been designed to reduce harmful levels of carbon monoxide (CO), hydrocarbons (HC) and nitrogen oxides (NOx) contained in diesel exhaust emissions. This engine has been certified to meet US EPA Evaporative emissions requirements in the installed configuration. Attempting to modify or make adjustments to the engine emission system by unauthorized personnel without proper training could damage the equipment or create an unsafe condition. Additionally, modifying the fuel system may adversely affect evaporative emissions, resulting in fines or other penalties. Emission Control Label The emission control label is an integral part of the emission system and is strictly controlled by regulation(s). The label must remain with the engine for its entire life. If a replacement emission label is needed, please contact your authorized engine distributor.