✨ Welcome to the new Discount Equipment site — same 36-year team, freshly redesigned.
36 Years of Industry Leadership · Trusted by Contractors Across America · U.S. Freight & Exporter-Friendly
MultiQuip

Multiquip GBC8LED GloBug Diffuser Balloon Light, 4 Wheel Cart w/3-Stage Mast Assembly, 800W LED

Part number
GBC8LED
Model
GBC8LED
Year
2/1/2026
Condition
New
$5723.15List $7894.00Save $2170.85

MultiQuip orders have a $50.00 minimum (Multiquip family)

Genuine OEMShips nationwideExpert support
GBC8LED: 800W LED, Diffuser Balloon Light, Cart Mounted w/3-stage mast assembly The ideal combination of the innovative GB8LED GloBug supported by an industrial grade cart for easy transportation and operational flexibility! The Steerable cart sets up without tools, includes a 3-stage air assisted mast assembly and provides the perfect platform to safely secure a selected portable generator for off-site lighting applications. (unit shown with an optional portable generator)
Multiquip GBC8LED GloBug Diffuser Balloon Light, 4 Wheel Cart w/3-Stage Mast Assembly, 800W LED • Steerable cart design for easy transportation - sets up without tools; easy to maneuver. • LED lighting offers superior color rendering, instant strike times, less heat signatures, long life and reduces overall operating costs. • Universally adaptable to all AC power supplies - accepts 50/60Hz, 115V. • Optional illuminance settings - 3-stage dimming controls (400W, 600W, 800W) • Cart is industrially designed with zinc plated surfaces for corrosion resistance • Three-stage mast - extends up to 10.5 ft. • The cart outriggers provide great stabilization • System can easily be broken down and placed in the bed of a truck. • Light coverage up to 132 feet.
Multiquip GBC8LED GloBug Diffuser Balloon Light Mount Type: Cart, Zinc Plated Steel w/ 3-Stage Air-Assisted mast Max. Height: 10.6' Total Weight: 127lb. Wind Limits: 25 MPH Lamp Assembly: Balloon: 47" x 28" Lamp (W): 800W LED Lumens: 110,000 (High) Voltage (V): 115 Current (A): 6.9A @115V Hertz (Hz): 50-60 Dimmer Switch: 400/600/800W Min. Generator: 1200 W
Multiquip GBC8LED GloBug Diffuser Balloon Light GENERAL SAFETY CAUTION NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations. NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication. NEVER operate this equipment under the influence of drugs or alcohol. ALWAYS check the equipment for loosened threads or bolts before starting. DO NOT use the equipment for any purpose other than its intended purposes or applications. NOTICE This equipment should only be operated by trained and qualified personnel 18 years of age and older. Whenever necessary, replace nameplate, operation and safety decals when they become difficult read. Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties. NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result. ALWAYS know the location of the nearest fire extinguisher. ALWAYS know the location of the nearest first aid kit. ALWAYS know the location of the nearest phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency. LIGHTING SYSTEM SAFETY WARNING NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties. CAUTION NEVER attempt service on a running machine. NOTICE To prevent the lighting system from overturning, NEVER use in winds that exceed 25 mph (11 m/s). The lighting system should only be used in temperatures between 14° to 104°F (10° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life. ALWAYS keep the lighting system in proper running condition. Fix damage to lighting system and replace any broken parts immediately. ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel. NOTICE NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp. ALWAYS make sure lamp surface is clean and dry. ALWAYS replace with MQ recommended type lamp. See parts section of this manual. If applicable, ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard. NEVER unplug the lamp’s AC power cable during operation. ALWAYS have a trained technician to install and remove lamp or replace any damaged fixture wiring. TRANSPORTING SAFETY NOTICE When transporting the pentapod lighting system, if applicable, always place in stow position and place pentapod in its carrying case. ALWAYS remove balloon/lamp assembly from the mast when transporting lighting system. This will prevent damage to the bulb due to vibration. NEVER leave the balloon/lamp exposed during transport. Exposure to excess wind or rain could damage the balloon’s nylon cover. ALWAYS place balloon inside its protective cover during transport. Be sure the cover is secured tightly around the balloon/lamp assembly. BALLOON SAFETY CAUTION ALWAYS keep the balloon away from sharp objects and excessive amounts of heat. NOTICE To prevent balloon deformation, NEVER use lighting system in strong winds. DO NOT place the balloon inside its protective cover until the lamp has had a sufficient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface). ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements. Replace balloon immediately if damaged. A damaged balloon will not inflate properly, and may become more damaged by touching the hot lamp surface. DO NOT use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable. MAST SAFETY CAUTION When raising or lowering the mast, keep hands and fingers clear of the various mast sections, this will prevent hands and fingers from getting pinched. NEVER attach anything to the mast. ALWAYS lower the mast when not in use, or if high winds or electrical storms are expected in the area ELECTRICAL SAFETY DANGER Lighting system is equipped with a ground pin on the power plug. For your protection, ALWAYS complete the grounding path. NEVER insert the AC power plug into a 2-prong receptacle to operate lighting system. When applying power to the lighting system, ALWAYS connect the AC power plug to a 3-prong receptacle that is grounded. The possibility exists of electrical shock, electrocution and even death if the lighting system is not grounded. NEVER operate lighting system or handle any electrical equipment while standing in water, while barefoot, while hands are wet or in the rain. A dangerous electrical shock could occur, causing severe bodily harm or even death. ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions. Contact with overhead power lines or other obstructions could result in equipment damage, electrical shock, electrocution and even death. Power Cord/Cable Safety DANGER NEVER let power cords or cables lay in water. NEVER use damaged or worn cables or cords. Inspect for cuts in the insulation NEVER grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death. Make sure power cables are securely connected. Incorrect connections may cause electrical shock and damage to the lighting system. NOTICE ALWAYS make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.